To stabilize a sinking garage foundation, we use Helical Pier Systems to transfer the structural weight of the garage away from failing surface soils and down to deeper, load-bearing strata. This process provides permanent stability where shallow soils can no longer support the structure.
The installation follows a precise professional sequence:
- Site Preparation and Excavation: We expose the existing footing, typically excavating 3 to 4 feet deep to reach the base of the foundation.
- Strategic Positioning: Using compact equipment that requires as little as four feet of headroom, we position the helical lead section under the footing.
- Hydraulic Rotation: We drive the pier shaft into the ground using hydraulic rotation. During this phase, we utilize real-time torque monitoring to verify that each pier reaches the exact engineered load specification required for your specific site.
- Bracket Attachment: Once the pier reaches the target torque value and depth, an underpinning repair bracket is secured to the pier and the existing concrete footing.
- Lift and Load Transfer: Using hydraulic equipment, the foundation is raised back to its correct level according to engineering plans. The structural load is then transferred through the brackets onto the piers.
This method is highly efficient as it avoids the long curing times associated with traditional concrete repairs. Because we adhere to ICC-ES AC358 standards, you can be confident that the repair is both safe and compliant with building codes.
Note: Before beginning, it is essential to consult a structural engineer. Through our network of structural engineers and Engineering Excellence and Design Support, we can help you obtain the required soil evaluations and load calculations to ensure a successful repair.
Related FAQs
-
How is the Soil Bearing Capacity Determined for Helical Pier Installation?
Read More »: How is the Soil Bearing Capacity Determined for Helical Pier Installation?To ensure long-term structural stability, we determine soil bearing capacity through a combination of upfront geotechnical investigations and real-time field verification during installation. Geotechnical Investigation Before installation begins, we recommend a site-specific geotechnical report to map the soil profile. This…
-
Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?
Read More »: Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?Yes, groundwater fluctuations are a critical factor in determining soil bearing capacity. A rising water table reduces the effective stress and overall strength of the soil, which in turn diminishes the load capacity of a helical pier. Because groundwater levels…
-
How do You Repair Stair-step Cracks in Brick Veneer?
Read More »: How do You Repair Stair-step Cracks in Brick Veneer?Repairing stair-step cracks in brick veneer requires a professional three-step approach that addresses the root cause of the movement rather than just providing a cosmetic fix. A professional must first determine if the crack is active. This involves using crack…
-
Do Stair-step Cracks Indicate a Sinking Foundation?
Read More »: Do Stair-step Cracks Indicate a Sinking Foundation?Yes, stair-step cracks are considered one of the most significant indicators of differential foundation settlement. These diagonal fractures follow the mortar joints in a zigzag pattern and develop when a foundation settles unevenly, creating stress that the rigid brick veneer…
-
Are Stair-step Cracks in Brick Safe to Ignore?
Read More »: Are Stair-step Cracks in Brick Safe to Ignore?No, stair-step cracks in brick should not be ignored. Because these cracks typically follow mortar joints in a diagonal pattern, they are considered a moderate-to-high severity indicator of differential foundation settlement. Ignoring these signs can lead to progressive structural damage…