Yes, corrosion is a critical factor that can cause helical piers to fail over time. It is an electrochemical reaction—primarily involving moisture and steel—that leads to progressive section loss of the pier shaft.
This process impacts structural integrity in several ways:
- Reduced Load Capacity: As the steel cross-section diminishes due to rust, the pier’s ability to support design loads decreases proportionally. This can lead to differential settlement or, in severe cases, cause the pier to buckle or fail entirely.
- Environmental Acceleration: Corrosion can be accelerated by soils with low electrical resistivity (high chloride, sulfate, or acid content), persistently high moisture levels, or stray DC currents from nearby utility lines and rail systems.
- Triggering Other Failures: A weakened shaft may become more susceptible to negative skin friction, where shifting surrounding soils grip the pier and exert downward pressure that the compromised steel can no longer withstand.
To mitigate these risks, it is essential to use products that meet ICC-ES AC358 standards, which require a minimum 0.002-inch hot-dip galvanized coating. In highly aggressive environments, additional protections like cathodic protection (using sacrificial anodes) may be necessary to ensure the pier’s long-term service life.
Related FAQs
-
What is the Relationship between Installation Torque and Soil Bearing Capacity?
Read More »: What is the Relationship between Installation Torque and Soil Bearing Capacity?Installation torque is used as a real-time indicator of soil bearing capacity because the rotational resistance encountered by the helix plates reflects the soil’s shear strength. As the helical pier advances into competent strata, the torque required to turn it…
-
How do Engineers Calculate the Ultimate Geotechnical Capacity of a Helical Pile?
Read More »: How do Engineers Calculate the Ultimate Geotechnical Capacity of a Helical Pile?To calculate the ultimate geotechnical capacity of a helical pile, we utilize two primary methodologies: the individual bearing method and the torque factor method. These approaches allow us to ensure structural loads are successfully transferred to competent bearing strata. $Q_{ult}…
-
Why is a Geotechnical Investigation Necessary to Verify Soil Bearing Capacity?
Read More »: Why is a Geotechnical Investigation Necessary to Verify Soil Bearing Capacity?A geotechnical investigation is essential because it provides the site-specific data required to identify competent bearing strata and accurately size helical pier systems. Relying on general benchmarks is insufficient because actual soil bearing capacity varies significantly based on moisture content,…
-
How is the Soil Bearing Capacity Determined for Helical Pier Installation?
Read More »: How is the Soil Bearing Capacity Determined for Helical Pier Installation?To ensure long-term structural stability, we determine soil bearing capacity through a combination of upfront geotechnical investigations and real-time field verification during installation. Geotechnical Investigation Before installation begins, we recommend a site-specific geotechnical report to map the soil profile. This…
-
Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?
Read More »: Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?Yes, groundwater fluctuations are a critical factor in determining soil bearing capacity. A rising water table reduces the effective stress and overall strength of the soil, which in turn diminishes the load capacity of a helical pier. Because groundwater levels…