Yes, corrosion is a critical factor that can cause helical piers to fail over time. It is an electrochemical reaction—primarily involving moisture and steel—that leads to progressive section loss of the pier shaft.
This process impacts structural integrity in several ways:
- Reduced Load Capacity: As the steel cross-section diminishes due to rust, the pier’s ability to support design loads decreases proportionally. This can lead to differential settlement or, in severe cases, cause the pier to buckle or fail entirely.
- Environmental Acceleration: Corrosion can be accelerated by soils with low electrical resistivity (high chloride, sulfate, or acid content), persistently high moisture levels, or stray DC currents from nearby utility lines and rail systems.
- Triggering Other Failures: A weakened shaft may become more susceptible to negative skin friction, where shifting surrounding soils grip the pier and exert downward pressure that the compromised steel can no longer withstand.
To mitigate these risks, it is essential to use products that meet ICC-ES AC358 standards, which require a minimum 0.002-inch hot-dip galvanized coating. In highly aggressive environments, additional protections like cathodic protection (using sacrificial anodes) may be necessary to ensure the pier’s long-term service life.
Related FAQs
-
Why do some Foundation Experts Recommend Steel Piers over Polyurethane Foam for Structural Issues?
Read More »: Why do some Foundation Experts Recommend Steel Piers over Polyurethane Foam for Structural Issues?We recommend steel piers over polyurethane foam when a permanent, engineered structural solution is required. While polyurethane foam is an effective tool for filling voids and performing minor, non-structural lifts for concrete slabs (typically under 2 inches), it is not…
-
What are the Pros and Cons of Polyurethane Foam Vs. Steel Piering?
Read More »: What are the Pros and Cons of Polyurethane Foam Vs. Steel Piering?When evaluating polyurethane foam vs steel piers, the choice depends on whether you need a temporary surface fix or a permanent structural repair. Polyurethane Foam Injection (Slab Jacking) Steel Piers (Helical or Push Piers) While foam is a suitable tool…
-
When should a Contractor or Homeowner Seek a Professional Foundation Inspection for a New Property?
Read More »: When should a Contractor or Homeowner Seek a Professional Foundation Inspection for a New Property?While all new buildings undergo a period of natural settling within the first few years as soil compresses, you should be concerned enough to seek a professional foundation inspection if you observe signs of differential settlement. Unlike uniform settling, differential…
-
Why might Cracks in Drywall or Masonry Appear in a New House During the First Few Years?
Read More »: Why might Cracks in Drywall or Masonry Appear in a New House During the First Few Years?Cracks in a new home typically fall into two categories: normal cosmetic shrinkage or signs of problematic foundation movement. Most buildings experience a degree of normal settling within the first few years as the soil compresses under the weight of…
-
Do Sticking Doors and Windows in a New Home Always Indicate Significant Foundation Settlement?
Read More »: Do Sticking Doors and Windows in a New Home Always Indicate Significant Foundation Settlement?No, sticking doors and windows in a new home do not always indicate significant foundation settlement. While they are recognized symptoms of structural movement, they can also be caused by several non-structural factors. In many cases, doors and windows may…