Polyurethane foam is generally not recommended for structural foundation stabilization. While it is an effective tool for slab jacking—which involves lifting non-structural concrete like sidewalks, driveways, or interior slabs with less than 2 inches of settlement—it lacks the capacity to support the perimeter foundations or load-bearing walls of a settling home.
For a permanent solution, we utilize foundation underpinning via steel pier systems. The primary differences include:
- Load-Bearing Capacity: Polyurethane foam is typically limited to lighter loads (under 20 tons). In contrast, our Helical Piers provide a load-bearing capacity that can exceed 100 tons per pier.
- Depth and Stability: Foam injection is a shallow correction that may degrade over time, especially in expansive clay or high-moisture soils. Our steel piers transfer the building’s load past unstable surface soils down to competent load-bearing strata or bedrock.
- Engineering Standards: Our Helical Pier Systems and Push Piers are ICC and ISO Certified products with ICC-ES documentation, ensuring they meet the highest industry standards for permanent structural support.
Because every project has unique soil conditions and structural requirements, we recommend a site-specific geotechnical evaluation. We provide Engineering Excellence and Design Support through our network of structural engineers to ensure your repair is built to last.
Note: Consult a structural engineer or our engineering team for project-specific design and installation guidance. Installations must comply with applicable building codes and ICC-ES acceptance criteria (AC358).
Related FAQs
-
What are the Asce 7 Requirements for Solar Pile Uplift?
Read More »: What are the Asce 7 Requirements for Solar Pile Uplift?According to the provided technical guide, the ASCE 7-22 standards establish specific safety factors and load combinations to determine the required uplift resistance capacity for helical piers in solar applications. Key requirements include: Engineers must use these factored loads in…
-
How do I Test for Solar Foundation Uplift Resistance on Site?
Read More »: How do I Test for Solar Foundation Uplift Resistance on Site?Testing for solar foundation uplift resistance on site involves a combination of real-time installation monitoring and physical verification tests to ensure the foundation can withstand significant wind loads. According to the provided guide, the following methods are used to test…
-
Does Helix Diameter Affect Uplift Resistance in Sandy Soils?
Read More »: Does Helix Diameter Affect Uplift Resistance in Sandy Soils?Yes, helix diameter significantly affects uplift resistance capacity. According to the provided technical guide, the dimensions and configuration of the helix plates are critical factors in determining how much upward force a pile can support. Key ways helix diameter influences…
-
What Factors Influence the Uplift Capacity of a Helical Pier?
Read More »: What Factors Influence the Uplift Capacity of a Helical Pier?The uplift resistance capacity of a helical pier is influenced by several geotechnical, structural, and mechanical factors. According to the provided guide, these include: Related FAQs
-
How is Uplift Resistance Capacity Calculated for Solar Helical Piles?
Read More »: How is Uplift Resistance Capacity Calculated for Solar Helical Piles?The uplift resistance capacity for solar helical piles is calculated by determining the maximum upward load a pile can support before failure. This is primarily established through two engineering methods: Engineers calculate the total capacity by summing the helix bearing…