While all new buildings undergo a period of natural settling within the first few years as soil compresses, you should be concerned enough to seek a professional foundation inspection if you observe signs of differential settlement. Unlike uniform settling, differential movement can threaten the structural integrity of a new property.
We recommend contacting a professional immediately if you notice any of the following red flags:
- Significant Cracking: Any cracks in foundation walls, floors, or drywall that exceed 1/8 inch in width. You should be particularly concerned by vertical, diagonal, or stair-step cracks, as well as cracks that widen or expand over time.
- Functional Distortion: Doors and windows that suddenly stick, fail to latch, or no longer close smoothly, indicating that the frames have become misaligned due to structural shifting.
- Visible Gaps: New gaps forming around exterior door or window frames, or instances where the brick veneer and siding are separating from the structure.
- Floor and Wall Issues: Noticeably sloping or uneven floors, bulging or leaning walls, or trim and molding that is separating from the ceiling or wall.
For homes built within the last five years, these indicators often suggest that the underlying soils have not reached equilibrium or that there is inadequate footing support. Only a licensed structural engineer can accurately differentiate between harmless cosmetic shrinkage and developing structural risks.
If an inspection confirms that stabilization is required, we offer a range of ICC- and ISO-certified foundation repair solutions, including helical pier systems and push piers. We also provide Engineering Excellence and Design Support to ensure repairs comply with all applicable building codes and ICC-ES acceptance criteria.
Consult a structural engineer or the manufacturer’s engineering team for project-specific design and installation guidance. Products are certified to ICC/ISO where indicated—installations must comply with applicable building codes and ICC-ES acceptance criteria (AC358).
Related FAQs
-
What is the Relationship between Installation Torque and Soil Bearing Capacity?
Read More »: What is the Relationship between Installation Torque and Soil Bearing Capacity?Installation torque is used as a real-time indicator of soil bearing capacity because the rotational resistance encountered by the helix plates reflects the soil’s shear strength. As the helical pier advances into competent strata, the torque required to turn it…
-
How do Engineers Calculate the Ultimate Geotechnical Capacity of a Helical Pile?
Read More »: How do Engineers Calculate the Ultimate Geotechnical Capacity of a Helical Pile?To calculate the ultimate geotechnical capacity of a helical pile, we utilize two primary methodologies: the individual bearing method and the torque factor method. These approaches allow us to ensure structural loads are successfully transferred to competent bearing strata. $Q_{ult}…
-
Why is a Geotechnical Investigation Necessary to Verify Soil Bearing Capacity?
Read More »: Why is a Geotechnical Investigation Necessary to Verify Soil Bearing Capacity?A geotechnical investigation is essential because it provides the site-specific data required to identify competent bearing strata and accurately size helical pier systems. Relying on general benchmarks is insufficient because actual soil bearing capacity varies significantly based on moisture content,…
-
How is the Soil Bearing Capacity Determined for Helical Pier Installation?
Read More »: How is the Soil Bearing Capacity Determined for Helical Pier Installation?To ensure long-term structural stability, we determine soil bearing capacity through a combination of upfront geotechnical investigations and real-time field verification during installation. Geotechnical Investigation Before installation begins, we recommend a site-specific geotechnical report to map the soil profile. This…
-
Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?
Read More »: Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?Yes, groundwater fluctuations are a critical factor in determining soil bearing capacity. A rising water table reduces the effective stress and overall strength of the soil, which in turn diminishes the load capacity of a helical pier. Because groundwater levels…