We recommend steel piers over polyurethane foam when a permanent, engineered structural solution is required. While polyurethane foam is an effective tool for filling voids and performing minor, non-structural lifts for concrete slabs (typically under 2 inches), it is not a permanent fix for structural foundation settlement.
Our advanced earth anchoring systems are designed to address the root cause of settlement by transferring building loads past unstable surface soils down to competent load-bearing strata or bedrock. There are three primary reasons why our engineering team and network of structural engineers prefer steel systems:
- Superior Load-Bearing Capacity: Steel helical or push piers can support loads exceeding 100 tons per pier. In contrast, polyurethane foam is generally limited to lifting slabs and supporting lighter loads, typically under 20 tons.
- Stability in Expansive or Wet Soils: In environments with high moisture or expansive clay, shallow solutions like foam can be compromised by soil movement. Steel piers bypass these active zones entirely, providing long-term durability that foam cannot match.
- Permanent Underpinning: Unlike foam, which may degrade or require re-application over time, our ICC and ISO Certified products provide a permanent foundation repair solution. Steel systems are the industry standard for perimeter foundations, load-bearing walls, and commercial columns.
Because every project presents unique geotechnical challenges, we provide Engineering Excellence and Design Support to ensure the right system is utilized.
Consult a structural engineer or the manufacturer’s engineering team for project-specific design and installation guidance. Products are certified to ICC/ISO where indicated — installations must comply with applicable building codes and ICC-ES acceptance criteria (AC358).
Related FAQs
-
How Much do Frost Resistant Concrete Footings Add to Deck Costs?
Read More »: How Much do Frost Resistant Concrete Footings Add to Deck Costs?While the provided content does not list a specific dollar amount for deck costs, it does outline the financial and labor factors that contribute to the overall price of frost-resistant footings in Nebraska. According to the source, the cost of…
-
How Deep should Deck Footings be in Omaha to Prevent Frost Heaving?
Read More »: How Deep should Deck Footings be in Omaha to Prevent Frost Heaving?In Omaha, Nebraska, deck footings must be set to a minimum depth of 42 inches below grade to comply with the International Code Council (ICC) building codes. This specific depth is required to place the bearing point of the footing…
-
What Happens to a Deck if the Footings are not Deep Enough?
Read More »: What Happens to a Deck if the Footings are not Deep Enough?When deck footings are not set deep enough, they become highly susceptible to a process called frost heave. This occurs when moisture in the soil freezes and expands, generating tremendous upward pressure that can have several damaging effects on the…
-
Why is Foundation Depth Critical for Nebraska Deck Builds?
Read More »: Why is Foundation Depth Critical for Nebraska Deck Builds?Foundation depth is critical for Nebraska deck builds primarily to combat the effects of frost heave, which occurs when moisture in the soil freezes and expands. In Nebraska, the frost line typically extends between 30 and 60 inches deep. If…
-
What are the Best Lead Generation Strategies for Helical Pier Contractors?
Read More »: What are the Best Lead Generation Strategies for Helical Pier Contractors?For helical pier contractors, effective lead generation relies on a strategic combination of technical credibility, local digital visibility, and structured referral networks. According to the source content, the best strategies include: Paid Search and Local SEO: Use Google Ads to…